IT Infrastructure by Talentum Technology

Enterprise-grade IT systems and data center solutions.

Data center and server room design and build: racks, structured cabling, power distribution, UPS and cooling, for clients across Alpharetta and the Atlanta metro.

From server rooms to complete data centers, we deliver reliable IT infrastructure including server/storage systems, UPS solutions, IP phone systems, and comprehensive backup solutions. Trust us to keep your operations running 24/7.

Every it infrastructure project starts with a free consultation: we assess your requirements, design the right solution, implement it with our own engineers, and back it with ongoing maintenance and 24/7 technical support.

Get a Free Consultation

IT Infrastructure — Frequently Asked Questions

Data center and server room design and build, enterprise hardware deployment, power and cooling planning, and infrastructure for mission-critical operations.

Yes. The same engineering discipline applies whether it's a single-rack server room for an office or an enterprise data center.

Redundant power and cooling design, structured cable management, monitoring, and maintenance plans with 24/7 technical support.
Scope

What IT Infrastructure covers

Server/Storage
Server and storage hardware installed into a properly designed rack environment, with power, cooling and cable management planned around it.
Server Room Systems
A purpose-built server room rather than a repurposed cupboard: racks, structured cabling, power distribution, cooling and environmental monitoring.
Data Center Construction
Full data centre build-out — white space and support space, resilient power paths, cooling with hot and cold aisle containment, structured cabling and monitoring.
Codes & Standards

What governs IT Infrastructure work

Commercial it infrastructure in Georgia is designed and inspected against published standards, not house rules. These are the ones that shape the scope of a project of this type.

ANSI/TIA-942
Telecommunications Industry Association Data centre telecommunications infrastructure: the rated topologies, redundancy expectations and the separation of distribution areas that define how a room is laid out.
ASHRAE TC 9.9 thermal guidelines
ASHRAE The temperature and humidity envelopes equipment is designed to operate in, and the containment strategies that keep supply and return air from mixing.
NFPA 75
National Fire Protection Association Fire protection of information technology equipment and the rooms that hold it — construction, detection and the handling of combustible material inside the space.
NEC Article 645
National Fire Protection Association Information technology equipment rooms: the alternative wiring provisions that apply only when a room meets every condition in the article, including the disconnecting means.
Insights

Guides on IT Infrastructure

Ready to Start Your IT Infrastructure Project?

Contact us for a free, no-obligation consultation. We typically respond within 24 hours.

Contact Us